Allergen, Food, Kidney Bean

LAB4091

Collect

Serum separator tube. Multiple specimen tubes should be avoided.

Patient Preparation

Multiple patient encounters should be avoided.

Specimen Preparation

Separate serum from cells ASAP or within 2 hours of collection. Transfer 0.25 mL serum plus 0.1 mL for each additional allergen ordered to an ARUP Standard Transport Tube. (Min: 0.25 mL plus 0.04 mL for each allergen ordered)

Unacceptable Conditions

Hemolyzed, icteric, or lipemic specimens.

Storage/Transport Temperature

Refrigerated.

Stability (from collection to initiation)

After separation from cells: Ambient: 48 hours; Refrigerated: 2 weeks; Frozen: 1 year

Performed

Sun-Sat

Methodology

Quantitative ImmunoCAP Fluorescent Enzyme Immunoassay

Reported

1-2 days

Synonyms

  • P. vulgaris var. mexicanus
  • ImmunoCAP f287
  • Red Kidney Bean
  • Phaseolus vulgaris
  • P. vulgaris var. humilis
  • LAB4091
  • KIDNEY

Reference Interval

Effective 02/18/2014
Reporting Range
(reported in kU/L)
Probability of IgE Mediated
Clinical Reaction
Class Scoring
Less than 0.10No significant level detected0
0.10 - 0.34Clinical relevance undetermined0/1
0.35 - 0.70Low1
0.71 - 3.50Low2
3.51 - 17.50High3
17.51 - 50.00Very high4
50.01 - 100.00Very high5
Greater than 100.00Very high6

Interpretive Data

Allergen results of 0.10-0.34 kU/L are intended for specialist use as the clinical relevance is undetermined. Even though increasing ranges are reflective of increasing concentrations of allergen-specific IgE, these concentrations may not correlate with the degree of clinical response or skin testing results when challenged with a specific allergen. The correlation of allergy laboratory results with clinical history and in vivo reactivity to specific allergens is essential. A negative test may not rule out clinical allergy or even anaphylaxis.

CPT Codes

86003
Collection

LAB4091

Collect

Serum separator tube. Multiple specimen tubes should be avoided.

Patient Preparation

Multiple patient encounters should be avoided.

Specimen Preparation

Separate serum from cells ASAP or within 2 hours of collection. Transfer 0.25 mL serum plus 0.1 mL for each additional allergen ordered to an ARUP Standard Transport Tube. (Min: 0.25 mL plus 0.04 mL for each allergen ordered)

Unacceptable Conditions

Hemolyzed, icteric, or lipemic specimens.

Storage/Transport Temperature

Refrigerated.

Stability (from collection to initiation)

After separation from cells: Ambient: 48 hours; Refrigerated: 2 weeks; Frozen: 1 year
Ordering

Performed

Sun-Sat

Methodology

Quantitative ImmunoCAP Fluorescent Enzyme Immunoassay

Reported

1-2 days

Synonyms

  • P. vulgaris var. mexicanus
  • ImmunoCAP f287
  • Red Kidney Bean
  • Phaseolus vulgaris
  • P. vulgaris var. humilis
  • LAB4091
  • KIDNEY
Result Interpretation

Reference Interval

Effective 02/18/2014
Reporting Range
(reported in kU/L)
Probability of IgE Mediated
Clinical Reaction
Class Scoring
Less than 0.10No significant level detected0
0.10 - 0.34Clinical relevance undetermined0/1
0.35 - 0.70Low1
0.71 - 3.50Low2
3.51 - 17.50High3
17.51 - 50.00Very high4
50.01 - 100.00Very high5
Greater than 100.00Very high6

Interpretive Data

Allergen results of 0.10-0.34 kU/L are intended for specialist use as the clinical relevance is undetermined. Even though increasing ranges are reflective of increasing concentrations of allergen-specific IgE, these concentrations may not correlate with the degree of clinical response or skin testing results when challenged with a specific allergen. The correlation of allergy laboratory results with clinical history and in vivo reactivity to specific allergens is essential. A negative test may not rule out clinical allergy or even anaphylaxis.

Administrative

CPT Codes

86003

Allergen, Food, Lobster

LAB4051

Collect

Serum separator tube. Multiple specimen tubes should be avoided.

Patient Preparation

Multiple patient encounters should be avoided.

Specimen Preparation

Separate serum from cells ASAP or within 2 hours of collection. Transfer 0.25 mL serum plus 0.1 mL for each additional allergen ordered to an ARUP Standard Transport Tube. (Min: 0.25 mL plus 0.04 mL for each allergen ordered)

Unacceptable Conditions

Hemolyzed, icteric, or lipemic specimens.

Storage/Transport Temperature

Refrigerated.

Stability (from collection to initiation)

After separation from cells: Ambient: 48 hours; Refrigerated: 2 weeks; Frozen: 1 year

Performed

Sun-Sat

Methodology

Quantitative ImmunoCAP Fluorescent Enzyme Immunoassay

Reported

1-2 days

Synonyms

  • H. americanus - American Lobster (Allergen, Food, Lobster)
  • Homarus gammarus - European Lobster (Allergen, Food, Lobster)
  • ImmunoCAP f80 (Allergen, Food, Lobster)
  • LAB4051
  • LOBSTER
  • LOBSTERIGE

Reference Interval

Effective 02/18/2014
Reporting Range
(reported in kU/L)
Probability of IgE Mediated
Clinical Reaction
Class Scoring
Less than 0.10No significant level detected0
0.10 - 0.34Clinical relevance undetermined0/1
0.35 - 0.70Low1
0.71 - 3.50Moderate2
3.51 - 17.50High3
17.51 - 50.00Very high4
50.01 - 100.00Very high5
Greater than 100.00Very high6

Interpretive Data

Allergen results of 0.10-0.34 kU/L are intended for specialist use as the clinical relevance is undetermined. Even though increasing ranges are reflective of increasing concentrations of allergen-specific IgE, these concentrations may not correlate with the degree of clinical response or skin testing results when challenged with a specific allergen. The correlation of allergy laboratory results with clinical history and in vivo reactivity to specific allergens is essential. A negative test may not rule out clinical allergy or even anaphylaxis.

CPT Codes

86003
Collection

LAB4051

Collect

Serum separator tube. Multiple specimen tubes should be avoided.

Patient Preparation

Multiple patient encounters should be avoided.

Specimen Preparation

Separate serum from cells ASAP or within 2 hours of collection. Transfer 0.25 mL serum plus 0.1 mL for each additional allergen ordered to an ARUP Standard Transport Tube. (Min: 0.25 mL plus 0.04 mL for each allergen ordered)

Unacceptable Conditions

Hemolyzed, icteric, or lipemic specimens.

Storage/Transport Temperature

Refrigerated.

Stability (from collection to initiation)

After separation from cells: Ambient: 48 hours; Refrigerated: 2 weeks; Frozen: 1 year
Ordering

Performed

Sun-Sat

Methodology

Quantitative ImmunoCAP Fluorescent Enzyme Immunoassay

Reported

1-2 days

Synonyms

  • H. americanus - American Lobster (Allergen, Food, Lobster)
  • Homarus gammarus - European Lobster (Allergen, Food, Lobster)
  • ImmunoCAP f80 (Allergen, Food, Lobster)
  • LAB4051
  • LOBSTER
  • LOBSTERIGE
Result Interpretation

Reference Interval

Effective 02/18/2014
Reporting Range
(reported in kU/L)
Probability of IgE Mediated
Clinical Reaction
Class Scoring
Less than 0.10No significant level detected0
0.10 - 0.34Clinical relevance undetermined0/1
0.35 - 0.70Low1
0.71 - 3.50Moderate2
3.51 - 17.50High3
17.51 - 50.00Very high4
50.01 - 100.00Very high5
Greater than 100.00Very high6

Interpretive Data

Allergen results of 0.10-0.34 kU/L are intended for specialist use as the clinical relevance is undetermined. Even though increasing ranges are reflective of increasing concentrations of allergen-specific IgE, these concentrations may not correlate with the degree of clinical response or skin testing results when challenged with a specific allergen. The correlation of allergy laboratory results with clinical history and in vivo reactivity to specific allergens is essential. A negative test may not rule out clinical allergy or even anaphylaxis.

Administrative

CPT Codes

86003

Allergen, Food, Milk (Cow's)

LAB4054

Collect

Serum separator tube. Multiple specimen tubes should be avoided.

Patient Preparation

Multiple patient encounters should be avoided.

Specimen Preparation

Separate serum from cells ASAP or within 2 hours of collection. Transfer 0.25 mL serum plus 0.1 mL for each additional allergen ordered to an ARUP Standard Transport Tube. (Min: 0.25 mL plus 0.04 mL for each allergen ordered)

Unacceptable Conditions

Hemolyzed, icteric, or lipemic specimens.

Storage/Transport Temperature

Refrigerated.

Stability (from collection to initiation)

After separation from cells: Ambient: 48 hours; Refrigerated: 2 weeks; Frozen: 1 year

Performed

Sun-Sat

Methodology

Quantitative ImmunoCAP Fluorescent Enzyme Immunoassay

Reported

1-2 days

Synonyms

  • Bos spp.
  • ImmunoCAP f2
  • MILK
  • LAB4054

Reference Interval

Effective 02/18/2014
Reporting Range
(reported in kU/L)
Probability of IgE Mediated
Clinical Reaction
Class Scoring
Less than 0.10No significant level detected0
0.10 - 0.34Clinical relevance undetermined0/1
0.35 - 0.70Low1
0.71 - 3.50Moderate2
3.51 - 17.50High3
17.51 - 50.00Very high4
50.01 - 100.00Very high5
Greater than 100.00Very high6

Interpretive Data

Allergen results of 0.10-0.34 kU/L are intended for specialist use as the clinical relevance is undetermined. Even though increasing ranges are reflective of increasing concentrations of allergen-specific IgE, these concentrations may not correlate with the degree of clinical response or skin testing results when challenged with a specific allergen. The correlation of allergy laboratory results with clinical history and in vivo reactivity to specific allergens is essential. A negative test may not rule out clinical allergy or even anaphylaxis.

CPT Codes

86003
Collection

LAB4054

Collect

Serum separator tube. Multiple specimen tubes should be avoided.

Patient Preparation

Multiple patient encounters should be avoided.

Specimen Preparation

Separate serum from cells ASAP or within 2 hours of collection. Transfer 0.25 mL serum plus 0.1 mL for each additional allergen ordered to an ARUP Standard Transport Tube. (Min: 0.25 mL plus 0.04 mL for each allergen ordered)

Unacceptable Conditions

Hemolyzed, icteric, or lipemic specimens.

Storage/Transport Temperature

Refrigerated.

Stability (from collection to initiation)

After separation from cells: Ambient: 48 hours; Refrigerated: 2 weeks; Frozen: 1 year
Ordering

Performed

Sun-Sat

Methodology

Quantitative ImmunoCAP Fluorescent Enzyme Immunoassay

Reported

1-2 days

Synonyms

  • Bos spp.
  • ImmunoCAP f2
  • MILK
  • LAB4054
Result Interpretation

Reference Interval

Effective 02/18/2014
Reporting Range
(reported in kU/L)
Probability of IgE Mediated
Clinical Reaction
Class Scoring
Less than 0.10No significant level detected0
0.10 - 0.34Clinical relevance undetermined0/1
0.35 - 0.70Low1
0.71 - 3.50Moderate2
3.51 - 17.50High3
17.51 - 50.00Very high4
50.01 - 100.00Very high5
Greater than 100.00Very high6

Interpretive Data

Allergen results of 0.10-0.34 kU/L are intended for specialist use as the clinical relevance is undetermined. Even though increasing ranges are reflective of increasing concentrations of allergen-specific IgE, these concentrations may not correlate with the degree of clinical response or skin testing results when challenged with a specific allergen. The correlation of allergy laboratory results with clinical history and in vivo reactivity to specific allergens is essential. A negative test may not rule out clinical allergy or even anaphylaxis.

Administrative

CPT Codes

86003

Allergen, Food, Navy Bean

LAB4092

Collect

Serum separator tube. Multiple specimen tubes should be avoided.

Patient Preparation

Multiple patient encounters should be avoided.

Specimen Preparation

Separate serum from cells ASAP or within 2 hours of collection. Transfer 0.25 mL serum plus 0.1 mL for each additional allergen ordered to an ARUP Standard Transport Tube. (Min: 0.25 mL plus 0.04 mL for each allergen ordered)

Unacceptable Conditions

Hemolyzed, icteric, or lipemic specimens.

Storage/Transport Temperature

Refrigerated.

Stability (from collection to initiation)

After separation from cells: Ambient: 48 hours; Refrigerated: 2 weeks; Frozen: 1 year

Performed

Sun-Sat

Methodology

Quantitative ImmunoCAP Fluorescent Enzyme Immunoassay

Reported

1-2 days

Synonyms

  • ImmunoCAP f15
  • Phaseolus vulgaris
  • Pinto Bean
  • White Bean
  • LAB4092
  • NAVY

Reference Interval

Effective 02/18/2014
Reporting Range
(reported in kU/L)
Probability of IgE Mediated
Clinical Reaction
Class Scoring
Less than 0.10No significant level detected0
0.10 - 0.34Clinical relevance undetermined0/1
0.35 - 0.70Low1
0.71 - 3.50Moderate2
3.51 - 17.50High3
17.51 - 50.00Very high4
50.01 - 100.00Very high5
Greater than 100.00Very high6

Interpretive Data

Allergen results of 0.10-0.34 kU/L are intended for specialist use as the clinical relevance is undetermined. Even though increasing ranges are reflective of increasing concentrations of allergen-specific IgE, these concentrations may not correlate with the degree of clinical response or skin testing results when challenged with a specific allergen. The correlation of allergy laboratory results with clinical history and in vivo reactivity to specific allergens is essential. A negative test may not rule out clinical allergy or even anaphylaxis.

CPT Codes

86003
Collection

LAB4092

Collect

Serum separator tube. Multiple specimen tubes should be avoided.

Patient Preparation

Multiple patient encounters should be avoided.

Specimen Preparation

Separate serum from cells ASAP or within 2 hours of collection. Transfer 0.25 mL serum plus 0.1 mL for each additional allergen ordered to an ARUP Standard Transport Tube. (Min: 0.25 mL plus 0.04 mL for each allergen ordered)

Unacceptable Conditions

Hemolyzed, icteric, or lipemic specimens.

Storage/Transport Temperature

Refrigerated.

Stability (from collection to initiation)

After separation from cells: Ambient: 48 hours; Refrigerated: 2 weeks; Frozen: 1 year
Ordering

Performed

Sun-Sat

Methodology

Quantitative ImmunoCAP Fluorescent Enzyme Immunoassay

Reported

1-2 days

Synonyms

  • ImmunoCAP f15
  • Phaseolus vulgaris
  • Pinto Bean
  • White Bean
  • LAB4092
  • NAVY
Result Interpretation

Reference Interval

Effective 02/18/2014
Reporting Range
(reported in kU/L)
Probability of IgE Mediated
Clinical Reaction
Class Scoring
Less than 0.10No significant level detected0
0.10 - 0.34Clinical relevance undetermined0/1
0.35 - 0.70Low1
0.71 - 3.50Moderate2
3.51 - 17.50High3
17.51 - 50.00Very high4
50.01 - 100.00Very high5
Greater than 100.00Very high6

Interpretive Data

Allergen results of 0.10-0.34 kU/L are intended for specialist use as the clinical relevance is undetermined. Even though increasing ranges are reflective of increasing concentrations of allergen-specific IgE, these concentrations may not correlate with the degree of clinical response or skin testing results when challenged with a specific allergen. The correlation of allergy laboratory results with clinical history and in vivo reactivity to specific allergens is essential. A negative test may not rule out clinical allergy or even anaphylaxis.

Administrative

CPT Codes

86003

Allergen, Food, Orange

LAB4056

Collect

Serum separator tube. Multiple specimen tubes should be avoided.

Patient Preparation

Multiple patient encounters should be avoided.

Specimen Preparation

Separate serum from cells ASAP or within 2 hours of collection. Transfer 0.25 mL serum plus 0.1 mL for each additional allergen ordered to an ARUP Standard Transport Tube. (Min: 0.25 mL plus 0.04 mL for each allergen ordered)

Unacceptable Conditions

Hemolyzed, icteric, or lipemic specimens.

Storage/Transport Temperature

Refrigerated.

Stability (from collection to initiation)

After separation from cells: Ambient: 48 hours; Refrigerated: 2 weeks; Frozen: 1 year

Performed

Sun-Sat

Methodology

Quantitative ImmunoCAP Fluorescent Enzyme Immunoassay

Reported

1-2 days

Synonyms

  • Citrus aurantium
  • Citrus cinensis
  • Citrus macracantha
  • Citrus sinensis
  • ImmunoCAP f33
  • Sweet Orange
  • ORANGE
  • LAB4056

Reference Interval

Effective 02/18/2014
Reporting Range
(reported in kU/L)
Probability of IgE Mediated
Clinical Reaction
Class Scoring
Less than 0.10No significant level detected0
0.10 - 0.34Clinical relevance undetermined0/1
0.35 - 0.70Low1
0.71 - 3.50Moderate2
3.51 - 17.50High3
17.51 - 50.00Very high4
50.01 - 100.00Very high5
Greater than 100.00Very high6

Interpretive Data

Allergen results of 0.10-0.34 kU/L are intended for specialist use as the clinical relevance is undetermined. Even though increasing ranges are reflective of increasing concentrations of allergen-specific IgE, these concentrations may not correlate with the degree of clinical response or skin testing results when challenged with a specific allergen. The correlation of allergy laboratory results with clinical history and in vivo reactivity to specific allergens is essential. A negative test may not rule out clinical allergy or even anaphylaxis.

CPT Codes

86003
Collection

LAB4056

Collect

Serum separator tube. Multiple specimen tubes should be avoided.

Patient Preparation

Multiple patient encounters should be avoided.

Specimen Preparation

Separate serum from cells ASAP or within 2 hours of collection. Transfer 0.25 mL serum plus 0.1 mL for each additional allergen ordered to an ARUP Standard Transport Tube. (Min: 0.25 mL plus 0.04 mL for each allergen ordered)

Unacceptable Conditions

Hemolyzed, icteric, or lipemic specimens.

Storage/Transport Temperature

Refrigerated.

Stability (from collection to initiation)

After separation from cells: Ambient: 48 hours; Refrigerated: 2 weeks; Frozen: 1 year
Ordering

Performed

Sun-Sat

Methodology

Quantitative ImmunoCAP Fluorescent Enzyme Immunoassay

Reported

1-2 days

Synonyms

  • Citrus aurantium
  • Citrus cinensis
  • Citrus macracantha
  • Citrus sinensis
  • ImmunoCAP f33
  • Sweet Orange
  • ORANGE
  • LAB4056
Result Interpretation

Reference Interval

Effective 02/18/2014
Reporting Range
(reported in kU/L)
Probability of IgE Mediated
Clinical Reaction
Class Scoring
Less than 0.10No significant level detected0
0.10 - 0.34Clinical relevance undetermined0/1
0.35 - 0.70Low1
0.71 - 3.50Moderate2
3.51 - 17.50High3
17.51 - 50.00Very high4
50.01 - 100.00Very high5
Greater than 100.00Very high6

Interpretive Data

Allergen results of 0.10-0.34 kU/L are intended for specialist use as the clinical relevance is undetermined. Even though increasing ranges are reflective of increasing concentrations of allergen-specific IgE, these concentrations may not correlate with the degree of clinical response or skin testing results when challenged with a specific allergen. The correlation of allergy laboratory results with clinical history and in vivo reactivity to specific allergens is essential. A negative test may not rule out clinical allergy or even anaphylaxis.

Administrative

CPT Codes

86003

Allergen, Food, Pea

LAB4057

Collect

Serum separator tube. Multiple specimen tubes should be avoided.

Patient Preparation

Multiple patient encounters should be avoided.

Specimen Preparation

Separate serum from cells ASAP or within 2 hours of collection. Transfer 0.25 mL serum plus 0.1 mL for each additional allergen ordered to an ARUP Standard Transport Tube. (Min: 0.25 mL plus 0.04 mL for each allergen ordered)

Unacceptable Conditions

Hemolyzed, icteric, or lipemic specimens.

Storage/Transport Temperature

Refrigerated.

Stability (from collection to initiation)

After separation from cells: Ambient: 48 hours; Refrigerated: 2 weeks; Frozen: 1 year

Performed

Sun-Sat

Methodology

Quantitative ImmunoCAP Fluorescent Enzyme Immunoassay

Reported

1-2 days

Synonyms

  • Common Pea (Allergen, Food, Pea)
  • Dry Pea (Allergen, Food, Pea)
  • Garden Pea (Allergen, Food, Pea)
  • Green Pea (Allergen, Food, Pea)
  • Greenpea (Allergen, Food, Pea)
  • ImmunoCAP f12 (Allergen, Food, Pea)
  • Pisum sativum (Allergen, Food, Pea)
  • Snow Pea (Allergen, Food, Pea)
  • Sugar Snap Pea (Allergen, Food, Pea)
  • PEA
  • LAB4057

Reference Interval

Effective 02/18/2014
Reporting Range
(reported in kU/L)
Probability of IgE Mediated
Clinical Reaction
Class Scoring
Less than 0.10No significant level detected0
0.10 - 0.34Clinical relevance undetermined0/1
0.35 - 0.70Low1
0.71 - 3.50Moderate2
3.51 - 17.50High3
17.51 - 50.00Very high4
50.01 - 100.00Very high5
Greater than 100.00Very high6

Interpretive Data

Allergen results of 0.10-0.34 kU/L are intended for specialist use as the clinical relevance is undetermined. Even though increasing ranges are reflective of increasing concentrations of allergen-specific IgE, these concentrations may not correlate with the degree of clinical response or skin testing results when challenged with a specific allergen. The correlation of allergy laboratory results with clinical history and in vivo reactivity to specific allergens is essential. A negative test may not rule out clinical allergy or even anaphylaxis.

CPT Codes

86003
Collection

LAB4057

Collect

Serum separator tube. Multiple specimen tubes should be avoided.

Patient Preparation

Multiple patient encounters should be avoided.

Specimen Preparation

Separate serum from cells ASAP or within 2 hours of collection. Transfer 0.25 mL serum plus 0.1 mL for each additional allergen ordered to an ARUP Standard Transport Tube. (Min: 0.25 mL plus 0.04 mL for each allergen ordered)

Unacceptable Conditions

Hemolyzed, icteric, or lipemic specimens.

Storage/Transport Temperature

Refrigerated.

Stability (from collection to initiation)

After separation from cells: Ambient: 48 hours; Refrigerated: 2 weeks; Frozen: 1 year
Ordering

Performed

Sun-Sat

Methodology

Quantitative ImmunoCAP Fluorescent Enzyme Immunoassay

Reported

1-2 days

Synonyms

  • Common Pea (Allergen, Food, Pea)
  • Dry Pea (Allergen, Food, Pea)
  • Garden Pea (Allergen, Food, Pea)
  • Green Pea (Allergen, Food, Pea)
  • Greenpea (Allergen, Food, Pea)
  • ImmunoCAP f12 (Allergen, Food, Pea)
  • Pisum sativum (Allergen, Food, Pea)
  • Snow Pea (Allergen, Food, Pea)
  • Sugar Snap Pea (Allergen, Food, Pea)
  • PEA
  • LAB4057
Result Interpretation

Reference Interval

Effective 02/18/2014
Reporting Range
(reported in kU/L)
Probability of IgE Mediated
Clinical Reaction
Class Scoring
Less than 0.10No significant level detected0
0.10 - 0.34Clinical relevance undetermined0/1
0.35 - 0.70Low1
0.71 - 3.50Moderate2
3.51 - 17.50High3
17.51 - 50.00Very high4
50.01 - 100.00Very high5
Greater than 100.00Very high6

Interpretive Data

Allergen results of 0.10-0.34 kU/L are intended for specialist use as the clinical relevance is undetermined. Even though increasing ranges are reflective of increasing concentrations of allergen-specific IgE, these concentrations may not correlate with the degree of clinical response or skin testing results when challenged with a specific allergen. The correlation of allergy laboratory results with clinical history and in vivo reactivity to specific allergens is essential. A negative test may not rule out clinical allergy or even anaphylaxis.

Administrative

CPT Codes

86003

Allergen, Food, Peanut

LAB4058

Collect

Serum separator tube. Multiple specimen tubes should be avoided.

Patient Preparation

Multiple patient encounters should be avoided.

Specimen Preparation

Separate serum from cells ASAP or within 2 hours of collection. Transfer 0.25 mL serum plus 0.1 mL for each additional allergen ordered to an ARUP Standard Transport Tube. (Min: 0.25 mL plus 0.04 mL for each allergen ordered)

Unacceptable Conditions

Hemolyzed, icteric, or lipemic specimens.

Storage/Transport Temperature

Refrigerated.

Stability (from collection to initiation)

After separation from cells: Ambient: 48 hours; Refrigerated: 2 weeks; Frozen: 1 year

Performed

Sun-Sat

Methodology

Quantitative ImmunoCAP Fluorescent Enzyme Immunoassay

Reported

1-2 days

Synonyms

  • Arachis hypogaea
  • Groundnut
  • ImmunoCAP f13
  • Monkeynut
  • LAB4058
  • PEANUT

Reference Interval

Effective 02/18/2014
Reporting Range
(reported in kU/L)
Probability of IgE Mediated
Clinical Reaction
Class Scoring
Less than 0.10No significant level detected0
0.10 - 0.34Clinical relevance undetermined0/1
0.35 - 0.70Low1
0.71 - 3.50Moderate2
3.51 - 17.50High3
17.51 - 50.00Very high4
50.01 - 100.00Very high5
Greater than 100.00Very high6

Interpretive Data

Allergen results of 0.10-0.34 kU/L are intended for specialist use as the clinical relevance is undetermined. Even though increasing ranges are reflective of increasing concentrations of allergen-specific IgE, these concentrations may not correlate with the degree of clinical response or skin testing results when challenged with a specific allergen. The correlation of allergy laboratory results with clinical history and in vivo reactivity to specific allergens is essential. A negative test may not rule out clinical allergy or even anaphylaxis.

CPT Codes

86003
Collection

LAB4058

Collect

Serum separator tube. Multiple specimen tubes should be avoided.

Patient Preparation

Multiple patient encounters should be avoided.

Specimen Preparation

Separate serum from cells ASAP or within 2 hours of collection. Transfer 0.25 mL serum plus 0.1 mL for each additional allergen ordered to an ARUP Standard Transport Tube. (Min: 0.25 mL plus 0.04 mL for each allergen ordered)

Unacceptable Conditions

Hemolyzed, icteric, or lipemic specimens.

Storage/Transport Temperature

Refrigerated.

Stability (from collection to initiation)

After separation from cells: Ambient: 48 hours; Refrigerated: 2 weeks; Frozen: 1 year
Ordering

Performed

Sun-Sat

Methodology

Quantitative ImmunoCAP Fluorescent Enzyme Immunoassay

Reported

1-2 days

Synonyms

  • Arachis hypogaea
  • Groundnut
  • ImmunoCAP f13
  • Monkeynut
  • LAB4058
  • PEANUT
Result Interpretation

Reference Interval

Effective 02/18/2014
Reporting Range
(reported in kU/L)
Probability of IgE Mediated
Clinical Reaction
Class Scoring
Less than 0.10No significant level detected0
0.10 - 0.34Clinical relevance undetermined0/1
0.35 - 0.70Low1
0.71 - 3.50Moderate2
3.51 - 17.50High3
17.51 - 50.00Very high4
50.01 - 100.00Very high5
Greater than 100.00Very high6

Interpretive Data

Allergen results of 0.10-0.34 kU/L are intended for specialist use as the clinical relevance is undetermined. Even though increasing ranges are reflective of increasing concentrations of allergen-specific IgE, these concentrations may not correlate with the degree of clinical response or skin testing results when challenged with a specific allergen. The correlation of allergy laboratory results with clinical history and in vivo reactivity to specific allergens is essential. A negative test may not rule out clinical allergy or even anaphylaxis.

Administrative

CPT Codes

86003

Allergen, Food, Pecan

LAB4059

Collect

Serum separator tube. Multiple specimen tubes should be avoided.

Patient Preparation

Multiple patient encounters should be avoided.

Specimen Preparation

Separate serum from cells ASAP or within 2 hours of collection. Transfer 0.25 mL serum plus 0.1 mL for each additional allergen ordered to an ARUP Standard Transport Tube. (Min: 0.25 mL plus 0.04 mL for each allergen ordered)

Unacceptable Conditions

Hemolyzed, icteric, or lipemic specimens.

Storage/Transport Temperature

Refrigerated.

Stability (from collection to initiation)

After separation from cells: Ambient: 48 hours; Refrigerated: 2 weeks; Frozen: 1 year

Performed

Sun-Sat

Methodology

Quantitative ImmunoCAP Fluorescent Enzyme Immunoassay

Reported

1-2 days

Synonyms

  • Carya illinoensis (Allergen, Food, Pecan)
  • Carya illinoinensis (Allergen, Food, Pecan)
  • Hickory Nut (Allergen, Food, Pecan)
  • ImmunoCAP f201 (Allergen, Food, Pecan)
  • LAB4059

Reference Interval

Effective 02/18/2014
Reporting Range
(reported in kU/L)
Probability of IgE Mediated
Clinical Reaction
Class Scoring
Less than 0.10No significant level detected0
0.10 - 0.34Clinical relevance undetermined0/1
0.35 - 0.70Low1
0.71 - 3.50Moderate2
3.51 - 17.50High3
17.51 - 50.00Very high4
50.01 - 100.00Very high5
Greater than 100.00Very high6

Interpretive Data

Allergen results of 0.10-0.34 kU/L are intended for specialist use as the clinical relevance is undetermined. Even though increasing ranges are reflective of increasing concentrations of allergen-specific IgE, these concentrations may not correlate with the degree of clinical response or skin testing results when challenged with a specific allergen. The correlation of allergy laboratory results with clinical history and in vivo reactivity to specific allergens is essential. A negative test may not rule out clinical allergy or even anaphylaxis.

CPT Codes

86003
Collection

LAB4059

Collect

Serum separator tube. Multiple specimen tubes should be avoided.

Patient Preparation

Multiple patient encounters should be avoided.

Specimen Preparation

Separate serum from cells ASAP or within 2 hours of collection. Transfer 0.25 mL serum plus 0.1 mL for each additional allergen ordered to an ARUP Standard Transport Tube. (Min: 0.25 mL plus 0.04 mL for each allergen ordered)

Unacceptable Conditions

Hemolyzed, icteric, or lipemic specimens.

Storage/Transport Temperature

Refrigerated.

Stability (from collection to initiation)

After separation from cells: Ambient: 48 hours; Refrigerated: 2 weeks; Frozen: 1 year
Ordering

Performed

Sun-Sat

Methodology

Quantitative ImmunoCAP Fluorescent Enzyme Immunoassay

Reported

1-2 days

Synonyms

  • Carya illinoensis (Allergen, Food, Pecan)
  • Carya illinoinensis (Allergen, Food, Pecan)
  • Hickory Nut (Allergen, Food, Pecan)
  • ImmunoCAP f201 (Allergen, Food, Pecan)
  • LAB4059
Result Interpretation

Reference Interval

Effective 02/18/2014
Reporting Range
(reported in kU/L)
Probability of IgE Mediated
Clinical Reaction
Class Scoring
Less than 0.10No significant level detected0
0.10 - 0.34Clinical relevance undetermined0/1
0.35 - 0.70Low1
0.71 - 3.50Moderate2
3.51 - 17.50High3
17.51 - 50.00Very high4
50.01 - 100.00Very high5
Greater than 100.00Very high6

Interpretive Data

Allergen results of 0.10-0.34 kU/L are intended for specialist use as the clinical relevance is undetermined. Even though increasing ranges are reflective of increasing concentrations of allergen-specific IgE, these concentrations may not correlate with the degree of clinical response or skin testing results when challenged with a specific allergen. The correlation of allergy laboratory results with clinical history and in vivo reactivity to specific allergens is essential. A negative test may not rule out clinical allergy or even anaphylaxis.

Administrative

CPT Codes

86003

Allergen, Food, Pork

LAB4061

Collect

Serum separator tube. Multiple specimen tubes should be avoided.

Patient Preparation

Multiple patient encounters should be avoided.

Specimen Preparation

Separate serum from cells ASAP or within 2 hours of collection. Transfer 0.25 mL serum plus 0.1 mL for each additional allergen ordered to an ARUP Standard Transport Tube. (Min: 0.25 mL plus 0.04 mL for each allergen ordered)

Unacceptable Conditions

Hemolyzed, icteric, or lipemic specimens.

Storage/Transport Temperature

Refrigerated.

Stability (from collection to initiation)

After separation from cells: Ambient: 48 hours; Refrigerated: 2 weeks; Frozen: 1 year

Performed

Sun-Sat

Methodology

Quantitative ImmunoCAP Fluorescent Enzyme Immunoassay

Reported

1-2 days

Synonyms

  • ImmunoCAP f26 (Allergen, Food, Pork)
  • Sus spp. (Allergen, Food, Pork)
  • LAB4061

Reference Interval

Effective 02/18/2014
Reporting Range
(reported in kU/L)
Probability of IgE Mediated
Clinical Reaction
Class Scoring
Less than 0.10No significant level detected0
0.10 - 0.34Clinical relevance undetermined0/1
0.35 - 0.70Low1
0.71 - 3.50Moderate2
3.51 - 17.50High3
17.51 - 50.00Very high4
50.01 - 100.00Very high5
Greater than 100.00Very high6

Interpretive Data

Allergen results of 0.10-0.34 kU/L are intended for specialist use as the clinical relevance is undetermined. Even though increasing ranges are reflective of increasing concentrations of allergen-specific IgE, these concentrations may not correlate with the degree of clinical response or skin testing results when challenged with a specific allergen. The correlation of allergy laboratory results with clinical history and in vivo reactivity to specific allergens is essential. A negative test may not rule out clinical allergy or even anaphylaxis.

CPT Codes

86003
Collection

LAB4061

Collect

Serum separator tube. Multiple specimen tubes should be avoided.

Patient Preparation

Multiple patient encounters should be avoided.

Specimen Preparation

Separate serum from cells ASAP or within 2 hours of collection. Transfer 0.25 mL serum plus 0.1 mL for each additional allergen ordered to an ARUP Standard Transport Tube. (Min: 0.25 mL plus 0.04 mL for each allergen ordered)

Unacceptable Conditions

Hemolyzed, icteric, or lipemic specimens.

Storage/Transport Temperature

Refrigerated.

Stability (from collection to initiation)

After separation from cells: Ambient: 48 hours; Refrigerated: 2 weeks; Frozen: 1 year
Ordering

Performed

Sun-Sat

Methodology

Quantitative ImmunoCAP Fluorescent Enzyme Immunoassay

Reported

1-2 days

Synonyms

  • ImmunoCAP f26 (Allergen, Food, Pork)
  • Sus spp. (Allergen, Food, Pork)
  • LAB4061
Result Interpretation

Reference Interval

Effective 02/18/2014
Reporting Range
(reported in kU/L)
Probability of IgE Mediated
Clinical Reaction
Class Scoring
Less than 0.10No significant level detected0
0.10 - 0.34Clinical relevance undetermined0/1
0.35 - 0.70Low1
0.71 - 3.50Moderate2
3.51 - 17.50High3
17.51 - 50.00Very high4
50.01 - 100.00Very high5
Greater than 100.00Very high6

Interpretive Data

Allergen results of 0.10-0.34 kU/L are intended for specialist use as the clinical relevance is undetermined. Even though increasing ranges are reflective of increasing concentrations of allergen-specific IgE, these concentrations may not correlate with the degree of clinical response or skin testing results when challenged with a specific allergen. The correlation of allergy laboratory results with clinical history and in vivo reactivity to specific allergens is essential. A negative test may not rule out clinical allergy or even anaphylaxis.

Administrative

CPT Codes

86003

Allergen, Food, Potato

LAB4062

Collect

Serum separator tube. Multiple specimen tubes should be avoided.

Patient Preparation

Multiple patient encounters should be avoided.

Specimen Preparation

Separate serum from cells ASAP or within 2 hours of collection. Transfer 0.25 mL serum plus 0.1 mL for each additional allergen ordered to an ARUP Standard Transport Tube. (Min: 0.25 mL plus 0.04 mL for each allergen ordered)

Unacceptable Conditions

Hemolyzed, icteric, or lipemic specimens.

Storage/Transport Temperature

Refrigerated.

Stability (from collection to initiation)

After separation from cells: Ambient: 48 hours; Refrigerated: 2 weeks; Frozen: 1 year

Performed

Sun-Sat

Methodology

Quantitative ImmunoCAP Fluorescent Enzyme Immunoassay

Reported

1-2 days

Synonyms

  • ImmunoCAP f35
  • Irish Potato
  • Solanum tuberosum
  • Spud
  • POTATO
  • LAB4062

Reference Interval

Effective 02/18/2014
Reporting Range
(reported in kU/L)
Probability of IgE Mediated
Clinical Reaction
Class Scoring
Less than 0.10No significant level detected0
0.10 - 0.34Clinical relevance undetermined0/1
0.35 - 0.70Low1
0.71 - 3.50Moderate2
3.51 - 17.50High3
17.51 - 50.00Very high4
50.01 - 100.00Very high5
Greater than 100.00Very high6

Interpretive Data

Allergen results of 0.10-0.34 kU/L are intended for specialist use as the clinical relevance is undetermined. Even though increasing ranges are reflective of increasing concentrations of allergen-specific IgE, these concentrations may not correlate with the degree of clinical response or skin testing results when challenged with a specific allergen. The correlation of allergy laboratory results with clinical history and in vivo reactivity to specific allergens is essential. A negative test may not rule out clinical allergy or even anaphylaxis.

CPT Codes

86003
Collection

LAB4062

Collect

Serum separator tube. Multiple specimen tubes should be avoided.

Patient Preparation

Multiple patient encounters should be avoided.

Specimen Preparation

Separate serum from cells ASAP or within 2 hours of collection. Transfer 0.25 mL serum plus 0.1 mL for each additional allergen ordered to an ARUP Standard Transport Tube. (Min: 0.25 mL plus 0.04 mL for each allergen ordered)

Unacceptable Conditions

Hemolyzed, icteric, or lipemic specimens.

Storage/Transport Temperature

Refrigerated.

Stability (from collection to initiation)

After separation from cells: Ambient: 48 hours; Refrigerated: 2 weeks; Frozen: 1 year
Ordering

Performed

Sun-Sat

Methodology

Quantitative ImmunoCAP Fluorescent Enzyme Immunoassay

Reported

1-2 days

Synonyms

  • ImmunoCAP f35
  • Irish Potato
  • Solanum tuberosum
  • Spud
  • POTATO
  • LAB4062
Result Interpretation

Reference Interval

Effective 02/18/2014
Reporting Range
(reported in kU/L)
Probability of IgE Mediated
Clinical Reaction
Class Scoring
Less than 0.10No significant level detected0
0.10 - 0.34Clinical relevance undetermined0/1
0.35 - 0.70Low1
0.71 - 3.50Moderate2
3.51 - 17.50High3
17.51 - 50.00Very high4
50.01 - 100.00Very high5
Greater than 100.00Very high6

Interpretive Data

Allergen results of 0.10-0.34 kU/L are intended for specialist use as the clinical relevance is undetermined. Even though increasing ranges are reflective of increasing concentrations of allergen-specific IgE, these concentrations may not correlate with the degree of clinical response or skin testing results when challenged with a specific allergen. The correlation of allergy laboratory results with clinical history and in vivo reactivity to specific allergens is essential. A negative test may not rule out clinical allergy or even anaphylaxis.

Administrative

CPT Codes

86003

More Articles...