LAB314
FIB
Collect
One 2.7 mL blue top (3.2% citrate plasma).
Also acceptable: One 1.8 mL blue top tube (3.2% sodium citrate).
All blue top tubes collected for coagulation assays that do not have a blood culture collected first must have a discard tube collected prior to filling. The discard tube should be another blue top tube in which greater than 1 mL of blood is collected.
Pediatric Collection
0.5 mL platelet poor plasma.
Unacceptable Conditions
Clotted sample; tube fill volume less than 70% or greater than 110%; more than 4 hours since collection; sample not properly identified; incorrect container; insufficient sample volume.
Storage/Transport Temperature
Internal: Deliver to lab immediately at ambient temperature.
Offsite: Separate plasma from cells as soon as possible. Place plasma in an aliquot container and transport to lab frozen.
Stability (from collection to initiation)
Whole blood: Ambient, 4 hours.
Platelet poor plasma aliquot: Ambient, 4 hours; Refrigerated, 4 hours; Frozen (-20 degrees C), 2 weeks; Frozen (-70 degrees C), 6 months.
Performed by
PCL Clinical Laboratory - Coagulation
Performed
Daily
Methodology
Mechanical clot detection
Reported
Same day
Synonyms
- LAB314
- FIB
Reference Interval
150-400 mg/dL
Performed by
PCL Clinical Laboratory - Coagulation
CPT Codes
85384
Collection |
LAB314
FIB
Collect
One 2.7 mL blue top (3.2% citrate plasma).
Also acceptable: One 1.8 mL blue top tube (3.2% sodium citrate).
All blue top tubes collected for coagulation assays that do not have a blood culture collected first must have a discard tube collected prior to filling. The discard tube should be another blue top tube in which greater than 1 mL of blood is collected.
Pediatric Collection
0.5 mL platelet poor plasma.
Unacceptable Conditions
Clotted sample; tube fill volume less than 70% or greater than 110%; more than 4 hours since collection; sample not properly identified; incorrect container; insufficient sample volume.
Storage/Transport Temperature
Internal: Deliver to lab immediately at ambient temperature.
Offsite: Separate plasma from cells as soon as possible. Place plasma in an aliquot container and transport to lab frozen.
Stability (from collection to initiation)
Whole blood: Ambient, 4 hours.
Platelet poor plasma aliquot: Ambient, 4 hours; Refrigerated, 4 hours; Frozen (-20 degrees C), 2 weeks; Frozen (-70 degrees C), 6 months.
Performed by
PCL Clinical Laboratory - Coagulation
Ordering |
Performed
Daily
Methodology
Mechanical clot detection
Reported
Same day
Synonyms
- LAB314
- FIB
Result Interpretation |
Reference Interval
150-400 mg/dL
Performed by
PCL Clinical Laboratory - Coagulation
Administrative |
CPT Codes
85384